Telefon ve e-posta Desteği
Sıkça Sorulan Sorular
Yazarlar İçin Teknik Bilgiler
İletişim Bilgileri
Ana Sayfaya Dönüş
 

Kongre Takvimi
Buradaki bilgiler JournalAgent™ online dergicilik sisteminden alınmaktadır.

The Anatolian Journal of Cardiology

Eisenmenger sendromlu hastaların ilk başvuru anındaki klinik ve hemodinamik özellikleri: Tersiyer merkez deneyimi [Anatol J Cardiol]
Anatol J Cardiol. 2012; 12(1): 11-15 | DOI: 10.5152/akd.2012.003  

Eisenmenger sendromlu hastaların ilk başvuru anındaki klinik ve hemodinamik özellikleri: Tersiyer merkez deneyimi

Hasan Güngör1, Serkan Ertugay2, Mehmet Fatih Ayık2, Emre Demir3, Çağatay Engin2, Tahir Yağdı4, Mustafa Özbaran5, Yüksel Atay6, Sanem Nalbantgil7
1Clinic of Cardiology, Aydın Medline Hospital, Aydın-Turkey
2Ege Üniversitesi Tıp Fakültesi, Kalp Damar Cerrahisi Anabilim Dalı, İzmir, Türkiye
3Ege Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, İzmir-Türkiye
4Ege Üniversitesi Tıp Fakültesi Kalp Damar Cerrahisi Anabilim Dalı, Bornova, İzmir, Türkiye
5Ege Üniversitesi Tıp Fakültesi, Kalp ve Damar Cerrahisi Anabilim Dalı, İzmir-Türkiye
6Ege Üniversitesi Tıp Fakültesi, Kalp Damar Cerrahisi Anabilim Dalı, İzmir-Türkiye
7Ege Üniversitesi Tıp Fakültesi Kardiyoloji Anabilim Dalı, İzmir, Türkiye

Amaç: Bu çalışmada tersiyer bir merkeze Eisenmenger sendromu (ES) tanısı ile başvuran olgular incelenmiştir. Yöntemler: Eisenmenger sendromu tanılı 20 olgunun verileri (ortalama yaş: 27.6+1.8 yıl, 7’si erkek) retrospektif olarak incelendi. Takibe başlan- dığı andaki demografik özellikleri, semptomları, fizik muayene, laboratuvar ve hemodinamik bulguları değerlendirildi. Bulgular: Kompleks konjenital bozukluk ile beraber görülen ventriküler septal defekt (VSD) (n=8, %40) ile izole VSD (n=7, %35) en sık altta yatan kalp hastalığı idi. İlk başvuru anındaki 6 dakika yürüme testi (6DYT) mesafesi 347.9±33.7 metre ve %75’i NYHA fonksiyonel sınıf 3 kapasiteye sahipti. Olguların hepsinde ES tanısı kateterizasyon ile konulmuştu ve kateter ile ölçülen ortalama sistolik pulmoner arteriyel basınç değeri 112.0±6.8 mmHg idi. Solunum fonksiyon testlerinden FVC (zorlu vital kapasite), FEV1 (zorlu ekspiratuvar hacim) ve FEV1/FVC değerleri sırasıyla 3.1±0.4, 2.5±0.4 L ve %76.7±3.3 idi. Bütün hastalara takibe başlandığı anda metabolik test yapıldı. VO2 max miktarı 16.7±1.0 ml/kg/dk ve VE/VCO2 oranı %53.9±3.2 idi. Kan gazı analizinde ise PH ve parsiyel karbondioksit basıncı normal sınırlarda olmasına rağmen oksijen satürasyonu ve parsiyel oksijen basıncı düzeyleri düşük idi. Sonuç: Eisenmenger sendromlu hastalarda en sık konjenital hastalık VSD’dir. Bu olgularda egzersiz kapasitesi kısıtlanmıştır ve bu kısıtlanma laboratuvar parametrelerine yansımaktadır.

Anahtar Kelimeler: Eisenmenger sendromu, hemodinamik parametreler, laboratuvar parametreleri


Clinical and hemodynamic features of Eisenmenger syndrome patients at the time of first admission: a tertiary referral-center experience

Hasan Güngör1, Serkan Ertugay2, Mehmet Fatih Ayık2, Emre Demir3, Çağatay Engin2, Tahir Yağdı4, Mustafa Özbaran5, Yüksel Atay6, Sanem Nalbantgil7
1Clinic of Cardiology, Aydın Medline Hospital, Aydın-Turkey
2Ege Üniversitesi Tıp Fakültesi, Kalp Damar Cerrahisi Anabilim Dalı, İzmir, Türkiye
3Ege Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, İzmir-Türkiye
4Ege Üniversitesi Tıp Fakültesi Kalp Damar Cerrahisi Anabilim Dalı, Bornova, İzmir, Türkiye
5Ege Üniversitesi Tıp Fakültesi, Kalp ve Damar Cerrahisi Anabilim Dalı, İzmir-Türkiye
6Ege Üniversitesi Tıp Fakültesi, Kalp Damar Cerrahisi Anabilim Dalı, İzmir-Türkiye
7Ege Üniversitesi Tıp Fakültesi Kardiyoloji Anabilim Dalı, İzmir, Türkiye

Objective: In this study, patients admitted with the diagnosis of Eisenmenger syndrome (ES) in a tertiary referral center were analyzed. Methods: The data of 20 consecutive patients (mean age: 27.6+1.8 years, 7 male and mean follow-up time: 35.6±9.1 months) with ES were ret- rospectively analyzed. Demographic characteristics, symptoms, physical examination, laboratory and hemodynamic parameters were analyzed at the time of first admission. Results: The most frequent underlying heart diseases were ventricular septal defect (VSD) with complex congenital disease (n: 8, 40%) and isolated VSD (n: 7, 35%). 6-minute walking test distance was 347.9±33.7 meters and 15 patients (75%) had a functional capacity of NYHA Class III, at the time of admission. ES was diagnosed with catheterization in all patients and mean systolic pulmonary arterial pressure measured by catheterization was 112±6.8 mmHg. Pulmonary function tests, FVC (forced vital capacity), FEV1 (forced expiratory volume), FEV1/FVC values were respectively, 3.1±0.4, 2.5±0.4 L and 76.7±3.3%. Metabolic tests were performed in all patients at the first visit. Mean VO2 max was 16.7 ±1.0 ml / kg/min and VE/VCO2 rate was 53.9±3.2%. Although PH and partial pressure of carbon dioxide levels were within normal range in blood gas analysis, oxygen saturation and partial pressure of oxygen levels were low. Conclusion: The most common underlying heart disease of ES patients is VSD. In this cases exercise capacity is restricted and this restriction is reflected in laboratory parameters

Keywords: Eisenmenger syndrome, hemodynamic parameters, laboratory parameters


Hasan Güngör, Serkan Ertugay, Mehmet Fatih Ayık, Emre Demir, Çağatay Engin, Tahir Yağdı, Mustafa Özbaran, Yüksel Atay, Sanem Nalbantgil. Clinical and hemodynamic features of Eisenmenger syndrome patients at the time of first admission: a tertiary referral-center experience. Anatol J Cardiol. 2012; 12(1): 11-15


ARAÇLAR
Tam Metin PDF
Yazdır
Alıntıyı İndir
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
E-Postala
Paylaş


Benzer makaleler
PubMed
Google Scholar




 

 
 

Online Kongre Hizmetleri
Kongre Web Sitesi
Bildiri Özeti Toplama ve Değerlendirme
Online Kayıt ve Konaklama
Elektronik Poster (e-poster)
Video Podcast, WebCast
Bilimsel Program Düzenleyici
Bildiri Özeti ve Tam Metin CD'leri
 

Online Kurumsal Hizmetler
Dernekler İçin Web Siteleri
Hakemli Dergiler İçin Online Makale Toplama
   ve Değerlendirme

Uluslararası Dizin Danışmanlığı
PubMed®, LinkOut® Hizmetleri
Online Çalışma Grupları
 

Referans
Çalıştığımız Online Hakemli Dergiler
Destek Verdiğimiz Kongreler
Yazarlar İçin Teknik Bilgiler

İletişim
Bize Ulaşın
LookUs

 
 
1999 - 2019 © LookUs Scientific

Bu sitede sözü edilen uygulamalara ait teknoloji, uygulama metodu, ekran görünüşleri; ticari marka, ticari görünüm, kanun dışı rekabet ve başka kanunlarca; yerel ve uluslararası copyright düzenlemeleri ile korunmuştur. Site üzerindeki herhangi bir metin ve imaj LookUs Bilişim Hizmetleri Ltd.'nin açık ve net izni olmadan kopyalanamaz veya dağıtılamaz.
Metinler ve şekiller içinde geçen gerçek şirket ve ürün adları, ilgili firmaların ticari markaları olabilir.