Telefon ve e-posta Desteği
Sıkça Sorulan Sorular
Yazarlar İçin Teknik Bilgiler
İletişim Bilgileri
Ana Sayfaya Dönüş
 

Kongre Takvimi
Buradaki bilgiler JournalAgent™ online dergicilik sisteminden alınmaktadır.

The Anatolian Journal of Cardiology

[Anatol J Cardiol]
Anatol J Cardiol. 2002; 2(1): 45-48

Do Mobile Telephones Have Adverse Effects on the Functions of Implantable Cardioverter-Defibrillators?

İzzet Tandoğan1, Mehmet İleri2, Ertan Yetkin3, Ahmet Temizhan4, Dursun Aras5, Alpay Turan Sezgin6, Funda Bıyıkoğlu7, Ali Şaşmaz8
1Department of Cardiology Faculty of Medicine, Cumhuriyet University, Sivas, Turkey
2Türkiye Yüksek İhtisas Hastanesi Kardiyoloji Kliniği, Ankara
3Cardiology Clinic Türkiye Yüksek İhtisas Hospital, Ankara
4Department of Cardiology, Türkiye Yüksek İhtisas Hospital, Ankara
5Türkiye Yüksek İhtisas Eğitim ve Araştırma Hastanesi, Kardiyoloji Kliniği, Ankara
6Turgut Özal Medical Center Department of Cardiology, Medical Faculty, İnönü University, Malatya
7Department of Cardiology, Türkiye Yüksek İhtisas Hospital, Ankara, Turkey
8Cardiology Clinic, Yüksek Ihtisas Hospital, Ankara

Objective: The aim of this study was to investigate the effects of widely used mobile telephones on the functions of implantable cardioverter-defibrillators (ICD). Methods: The study included 9 patients (2 women, 7 men, mean age 65.5±6) with coronary artery disease who had underwent transvenous ICD implantation due to sustained ventricular tachycardia and/or fibrillation. First the test was performed on the basal conditions of ICD. Then, spontaneous heart rate of the patient was programmed to 10 beats/minute on VVI mode and the test was repeated. Two mobile telephones were located symmetrically 50 cm, 30 cm, 20 cm and 10 cm away from the ICD pocket in the pectoralis muscle and finally the mobile telephones antennas were touched to the pockets. On these different distances, the test was repeated during opening, standby, calling, talking and closing of the telephones. Possible ICD dysfunctions such as improper antitachycardic shock, inhibition of pacemaker functions, conversion to ventricular asynchronous mode (VOO) and development of ventricular trigger in devices with two chamber pacemaker functions were tested. The changes were observed on intracardiac and surface ECG’s. Results: There were no changes in the basal and pacemaker functions of ICD’s and no symptoms in any patients. Conclusion: We have concluded that mobile telephones have no adverse effects on the functions of types of ICD assessed in the study.



İzzet Tandoğan, Mehmet İleri, Ertan Yetkin, Ahmet Temizhan, Dursun Aras, Alpay Turan Sezgin, Funda Bıyıkoğlu, Ali Şaşmaz. Do Mobile Telephones Have Adverse Effects on the Functions of Implantable Cardioverter-Defibrillators?. Anatol J Cardiol. 2002; 2(1): 45-48


ARAÇLAR
Tam Metin PDF
Yazdır
Alıntıyı İndir
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
E-Postala
Paylaş


Benzer makaleler
PubMed
Google Scholar




 

 
 

Online Kongre Hizmetleri
Kongre Web Sitesi
Bildiri Özeti Toplama ve Değerlendirme
Online Kayıt ve Konaklama
Elektronik Poster (e-poster)
Video Podcast, WebCast
Bilimsel Program Düzenleyici
Bildiri Özeti ve Tam Metin CD'leri
 

Online Kurumsal Hizmetler
Dernekler İçin Web Siteleri
Hakemli Dergiler İçin Online Makale Toplama
   ve Değerlendirme

Uluslararası Dizin Danışmanlığı
PubMed®, LinkOut® Hizmetleri
Online Çalışma Grupları
 

Referans
Çalıştığımız Online Hakemli Dergiler
Destek Verdiğimiz Kongreler
Yazarlar İçin Teknik Bilgiler

İletişim
Bize Ulaşın
LookUs

 
 
1999 - 2019 © LookUs Scientific

Bu sitede sözü edilen uygulamalara ait teknoloji, uygulama metodu, ekran görünüşleri; ticari marka, ticari görünüm, kanun dışı rekabet ve başka kanunlarca; yerel ve uluslararası copyright düzenlemeleri ile korunmuştur. Site üzerindeki herhangi bir metin ve imaj LookUs Bilişim Hizmetleri Ltd.'nin açık ve net izni olmadan kopyalanamaz veya dağıtılamaz.
Metinler ve şekiller içinde geçen gerçek şirket ve ürün adları, ilgili firmaların ticari markaları olabilir.